Logo Goletty

Measuring System for Longtime Monitoring and Visualization of Temperature and Toxic Gases Concentration
Journal Title Electronics and Electrical Engineering
Journal Abbreviation elt
Publisher Group Kaunas University of Technology (KTU) Open Journal Systems (KTU)
Website http://www.eejournal.ktu.lt/index.php/elt
PDF (868 kb)
   
Title Measuring System for Longtime Monitoring and Visualization of Temperature and Toxic Gases Concentration
Authors Hajovsky, R.; Pies, M.
Abstract The contribution describes a developed measuring system intended for long-term monitoring of temperatures and hazardous gas concentrations within old mining dumps affected by thermal processes. It includes a short introduction describing the creation of thermal processes, including related hazards and impact on the environment. Furthermore, the contribution provides a detailed analysis of sensors for measuring CO and CH4 gas concentrations. It provides the advantages and disadvantages of the individual sensors, including the experience with their use. The conclusion contains a description of the complex measuring chain, including the data transfer technology and visualization at the dispatching station. Ill. 5, bibl. 7 (in English; abstracts in English and Lithuanian).DOI: http://dx.doi.org/10.5755/j01.eee.122.6.1838
Publisher Kaunas University of Technology
Date 2012-06-11
Source Elektronika ir elektrotechnika Vol 122, No 6 (2012)
Rights Autorių teisės yra apibrėžtos Lietuvos Respublikos autorių teisių ir gretutinių teisių įstatymo 4-37 straipsniuose.

 

See other article in the same Issue


Goletty © 2024